Fiber jumper ceev faj

Feb 17, 2022

Thaum sib txuas, ib qho kawg ntawm cov tub ntxhais fiber ntau yuav tsum tau txiav nrog lub cuab yeej ua ntej, lwm qhov kawg yuav tsum tau hla mus rau sab laug ntawm lub koob yees duab txee, thiab tus Tsov tus tw ntxiv yuav tsum raug mob rau hauv lub voj voog thiab qhwv nrog cov kab xev hluav taws xob, thiab tom qab ntawd lwm kawg Txuas lub cuab yeej lossis ODF khib. ODF khib nkag mus rau hauv lub cable los ntawm lub qhov nyob rau sab laug ntawm ODF khib. Ceev faj kom tsis txhob muaj cov kab hluav taws xob ya.


       After the patch fiber is terminated, label paper should be attached, and the label should be marked according to the naming requirements. After the label is affixed, rush to register the use of the ODF frame core. For example, if the trunk fiber core is jumpered, the use of the trunk fiber core (the local end and opposite end information written on the label paper) should be recorded and used. Notepad to record. Then, collect the protective caps of the modules and pigtails and put them in the small box at the bottom of the cabinet for future use.


Kev ua tiav tom qab lub jumper tiav kuj tseem ceeb heev:

①Test whether the fiber core is connected and whether the jumper target has been completed;

②After confirming that the fiber jumper work is successfully completed, organize the tools on site, and clean up the pigtail packaging bags and other garbage to keep the environment of the equipment room clean and tidy;

③Turn off the lights in the computer room, check again whether there is anything left in the computer room, and lock the door of the computer room when leaving.

Y0-54hIAQCiGM1D8AdBGBQ

Ntawm - qhov chaw npaj ua ntej fiber ntau jumpers suav nrog:


        ① Untie the pigtail tape, and unfold the two pigtails separately. After they are fully unfolded, the same interfaces are connected together. After straightening, the two jumpers are bundled together with electrical tape;


        ②If the fiber cores in different computer rooms are jumpered, you can contact the colleagues in the remote computer room by phone first to test whether the pigtails can be used normally, whether the ODF rack surface is wrong, and test whether the optical loss of the cables is normal; if it is the equipment in the computer room where the site is located Interconnect, connect related equipment, and test whether the pigtail can be used normally;


        ③Use a notepad to copy down the serial number of the module to be used, the length and type of the fiber core to facilitate asset management.